By using an extended bonnet, the packing, gaskets and seals of ColdFlow valves are protected from cryogenic temperatures, thus ensuring their sealing properties. Optional special gaskets and packing can be used to operate at temperatures as low as -69 °C. Depending on the application, Flowserve cryogenic valves are available with a top entry design for the easy maintenance of valves located in a cold box or with a simple extended bonnet attached to the valve body.
| Body | Angle |
| Trim | Plug & Clamped Seat, Special Cage & Stack Designs |
| Bonnet | Cold Box Extended, Cryogenic, Bellows Seal |
| Guiding | Double Top Stem Internal to Bonnet & Extension |
| Packing | Standard, Environment Fugitive Emissions, Live-Loaded, Oxygen Service |
| Seating | Metal-to-Metal & Soft |
| Valve Size | 1" to 8" |
| End Connections | Socket Weld, Butt Weld |
| Pressure Class Range | Class 150, 300, 600 |
| Trim Characteristics | Equal Percentage, Linear, Quick-Open |
| Face-to-Face Standard | Manufacturer Standard |
| Pressure Class Standard | ASME B16.34 |
| Shut-Off Classification | ANSI FCI 70-2 Class IV, V, VI |
| Certifications | Canadian Registration Number (CRN) |
| Design Standards | ASME B16.9 – Factory-Made Wrought Buttwelding Fittings |
| ASME B16.10 – Face to Face & End Dimensions of Valves | |
| ASME B16.25 – Buttwelding Ends | |
| ASME B16.34 – Valve Flanged, Threaded, and Welding End | |
| ASME SA Materials | |
| ASTM A Materials | |
| Quality | IS0 9001:2008 |
| ATEX QAN | |
| IECEX QAR |